Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
This table contains the following columns:
● System Name
System name of the connected device.
● Device ID
Device ID of the connected device. The device ID corresponds to the device name assigned
via PST (STEP 7). If no device name is assigned, the MAC address of the device is
displayed.
● Local Interface
Port at which the IE switch received the information.
● Hold Time
An entry remains stored on the device for the time specified here. If the IE switch does not
receive any new information from the connected device during this time, the entry is deleted.
● Capability
Shows the properties of the connected device:
– Router
– Bridge
– Telephone
– DOCSIS Cable Device
– WLAN Access Point
– Repeater
– Station
– Other
● Port ID
Port of the device with which the IE switch is connected.
5.3.12

Fiber Monitoring Protocol

Monitoring optical links
With Fiber Monitoring, you can monitor optical links. The table shows the current status of the
ports.
You set the values to be monitored on the following page: "Layer 2 > FMP".