● Retrans. Interval
Enter the time after which a packet is transferred again if no confirmation was received.
Range of values: 1 s to 3600 s
Default: 5 s
● Hello Interval
Enter the interval between two Hello packets.
Range of values: 1 s to 65,535 s
Default: 10 s
● Dead Interval
Enter the interval after which the neighbor router counts as "failed" if no more Hello packets
are received from it during this time.
Default setting: 60 s
Steps in configuration
1. Enter the ID of the neighbor router at the other end of the virtual link.
2. Select the area ID that connects the two routers.
3. Click the "Create" button. A new entry is generated in the table.
4. Enter suitable values in "Trans. Delay", "Retrans. Interval" and "Dead Interval".
5. Click the "Set Values" button.
5.7.9

RIPng

5.7.9.1

RIPng Configuration

On this page, you configure routing with RIPng.
Note
RIPng is available only on layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu