5.5.17.4

Multicast blocking

Disabling the forwarding of unknown multicast frames
On this page, you can block the forwarding of unknown multicast frames for individual ports.
Description of the displayed values
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– Enabled
– Disabled
– No change
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
All available ports are listed in this column. Unavailable ports are not displayed.
● Setting
Enable or disable the blocking of multicast frames.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Blocking of multicast frames is enabled.
Blocking of unknown multicast frames is disabled.
Table 2 remains unchanged.