Troubleshooting/FAQ

6.1

Firmware update - via WBM

Requirement
● The device has an IP address.
● The user is logged in with administrator rights.
Firmware update via HTTP
1. Click "System > Load&Save" in the navigation area. Click the "HTTP" tab.
2. Click the "Load" button in the "Firmware" table row.
3. Go to the storage location of the firmware file.
4. Click the "Open" button in the dialog. The file is uploaded.
Firmware update - via TFTP
1. Click "System > Load&Save" in the navigation area. Click the "TFTP" tab.
2. Enter the IP address of the TFTP server in the "TFTP Server Address" input box.
3. Enter the port of the TFTP server in the "TFTP Server Port" input box.
4. Click the "Load file" button in the "Firmware" table row.
5. Go to the storage location of the firmware file.
6. Click the "Open" button in the dialog. The file is uploaded.
Result
The firmware is has been transferred completely to the device.
On the "Information > Versions" there are the entries "Firmware" and "Firmware Running".
Firmware Runningshows the version of the current firmware. "Firmware" shows the firmware
version stored after loading the firmware. To activate this firmware, restart the device with
"System > Restart".
6.2

Firmware update via WBM or CLI not possible

Cause
If there is a power failure during the firmware update, it is possible that the IE switch is no
longer accessible using Web Based Management or the Command Line Interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
6
481