Interface & Value Match - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Settings
Figure 5-17
● Name
Enter the name for the route map.
● Sequence Number
Enter a number for the route map.
You can create several route maps with the same name but with different sequence
numbers. The sequence numbers then specify the order in which the route maps are
processed.
The table has the following columns:
● Select
Select the row you want to delete.
● Name
Shows the name of the route map.
● Sequence Number
Shows the sequence number of the route map.
● Action
Specify what happens to the routing information that matches the settings of the route map:
– permit
– deny
5.7.5.2
Interface & Value Match
On this page, you specify whether or not the routing information for a route map is filtered
according to interfaces, metric or tags.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Route maps general
The routing information is further processed according to the settings you make in the
"Set" tab.
The routing information is discarded.
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu