5.8.6

IP ACL

5.8.6.1

Rules Configuration

Introduction
On this page, you specify the rules for the IP-based Access Control List. Using the IP-based
ACL, you can specify whether frames of certain IPv4 addresses are forwarded or discarded.
Description of the displayed boxes
The table has the following columns:
● Select
Select the row you want to delete. If this entry is used, this is grayed out and you cannot
delete it.
● Rule Number
Shows the number of the ACL rule. If you create a new entry, a new line with a unique
number is created.
● Source IP
Enter the IPv4 address of the source.
● Source Subnet Mask
Enter the subnet mask of the source.
● Dest. IP
Enter the IPv4 address of the destination.
● Dest. Subnet Mask
Enter the subnet mask of the destination.
● Action
Select whether the frame is forwarded or rejected when it corresponds to the ACL rule.
– Forward
– Discard
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
If the frame complies with the ACL rule, the frame is forwarded.
If the frame complies with the ACL rule, the frame is not forwarded.