Siemens SCALANCE XM-400 Configuration Manual page 151

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

● SNMP
Select the protocol from the drop-down list. The following settings are possible:
– "-" (SNMP disabled)
– SNMPv1/v2c/v3
– SNMPv3
● SNMPv1/v2 Read-Only
Enable or disable write access to SNMP variables with SNMPv1/v2c.
● SNMPv1 Traps
Enable or disable the sending of traps (alarm frames). You can configure other settings in
"System > SNMP > Traps".
● SINEMA configuration interface
If the SINEMA configuration interface is enabled, you can download configurations to the
IE switch via the TIA Portal.
● NFC(only for SCALANCE XM-400)
Activate or deactivate the "NFC" (Near Field Communication) function.
You will find further information on NFC in the "SCALANCE XM400" Operating Instructions.
● Configuration Mode
Select the mode from the drop-down list. The following modes are possible:
– Automatic Save
– Trial
Steps in configuration
1. To use the required function, select the corresponding check box.
2. Select the options you require from the drop-down lists.
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Access to device parameters via SNMP is not possible.
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
Access to device parameters is possible only with SNMP version 3. You can configure
other settings in "System > SNMP > General".
Automatic backup mode. Approximately 1 minute after the last parameter change or
when you restart the device, the configuration is automatically saved.
Trial mode. In Trial mode, although changes are adopted, they are not saved in the
configuration file (startup configuration).
To save changes in the configuration file, use the "Write startup config" button. The
"Write startup config" button is displayed when you set trial mode. The display area also
shows the message "Trial Mode Active – Press "Write Startup Config" button to make
your settings persistent" as soon as there are unsaved modifications. This message can
be seen on every WBM page until the changes made have either been saved or the
device has been restarted.