The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Interface Name
Shows the name of the interface.
● IPv6 Address
Shows the IP address of the subnet.
● Prefix Length
Shows the prefix length.
● IPv6 Address Type
Displays the address type. The following values are possible:
– Unicast
– Anycast
– Link Local
● Loopback
Shows whether or not the "loopback" property is enabled. You configure the "loopback"
property on the page "Layer 3 (IPv4) > Subnets > Overview".
Steps in configuration
Forming a link local address automatically
1. Select the required interface.
2. Enable IPv6.
3. Click the "Create" button. In the table an entry with the interface is created and the
automatically formed IPv6 address is displayed.
Assigning link local address
1. Select the required interface.
2. Enable IPv6.
3. In "IPv6 Address" enter the link local address, e.g. FE80::21B:1BFF:FE40:9155
4. Enter "128" in "Prefix Length".
5. For "IPv6 Address Type" select the entry "Link Local".
6. Click the "Create" button. In the table an entry with the interface is created and the IPv6
address is displayed.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu