● IP Address
Enter an IPv4 address.
In the "DHCP Server" tab, the boxes "Lower IP Address" and "Upper IP Address" are filled
accordingly.
● Subnet Mask
Enter a corresponding subnet mask.
In the "DHCP Server" tab, the "Subnet" box is filled accordingly.
Procedure
Assign an IP address to the port
1. Select the required port.
2. Enter the IPv4 address and the subnet mask.
3. Click the "Set Values" button.
In the "Port Range" tab only the selected port is enabled for the relevant DHCP pool.
In the "DHCP Server" tab, the boxes "Subnet", "Lower IP Address" and "Upper IP Address"
are filled accordingly for the relevant DHCP pool.
5.4.9.4

Port Range

On this page, you define the ports via which the IPv4 addresses of an address band are
assigned.
After you have created an IPv4 address band in the "DHCP Server" tab, a new line is created
in this tab and all ports selected that are currently located in the corresponding VLAN. If you
add ports to the VLAN later, the ports are not automatically enabled in this tab.
Description
This table contains the following columns:
● Pool ID
Shows the number of the IPv4 address band. A line is created for every address band.
● Interface
Shows the assigned IP interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Configuring with Web Based Management