Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Settings
Figure 5-16
● IP Address
Select the IPv4 address of the RIPv2 interface.
This table contains the following columns:
● Select
Select the row you want to delete.
● IP Address
Shows the IPv4 address of the RIPv2 interface
● Send Updates
Select the way in which updates are sent:
– no send
– RIPv1
– RIPv1-compat.
– RIPv2
– RIPv1 demand/RIPv2 demand
394
RIPv2 interfaces
No updates are sent.
Updates for RIPv1 are sent.
RIPv2 updates are sent as broadcasts according to the rules of RIPv1.
Updates for RIPv2 are sent as multicasts.
RIP packets are sent only as a response to an explicit query.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12