Siemens SCALANCE XM-400 Configuration Manual page 433

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Description
The page contains the following:
● Area ID
Enter the designation of the area. The database is synchronized for all routers of an area.
The area identifier must be unique in the network.
The area identifier is a 32-bit number with the following format: x.x.x.x where x = 0 ... 255
The area identifier 0.0.0.0 is reserved for the backbone area and cannot be deleted.
This table contains the following columns:
● Select
Select the check box in the row to be deleted.
● Area ID
Shows the designation of the area.
● Area Type
Specify the type of area.
– Normal
– Stub
– NSSA
– Backbone
● Summary
Specify whether summary LSAs are generated for this area.
– Summary: Summary LSAs are generated and sent to the area.
– No Summary: Summary LSAs are not generated and sent to the area.
● Metric
Displays the costs for the OSPFv3 interface.
● Updates
Shows the number of recalculations of the routing tables.