Description of the device

3.5 C-PLUG

If there is a connection problem and the type of transmission is fixed (autonegotiation off),
the desired status, in other words the set transmission speed (1000 Mbps, 100 Mbps, 10
Mbps) continues to be displayed. If there is a connection problem and autonegotiation is
active, the port LED goes off.
Meaning in display mode C
In display mode C, the port LEDs indicate the mode.
LED color
-
Green
Meaning in display mode D
In display mode D, the port LEDs indicate whether the port is monitored.
LED color
-
Green
3.5
C-PLUG
3.5.1

Function of the C-PLUG

NOTICE
Do not remove or insert a C-PLUG during operation
A C-PLUG may only be removed or inserted when the device is turned off.
Saving the configuration data
A C-PLUG is an exchangeable storage medium for storing the configuration data of the
device. This allows fast and uncomplicated replacement of a device. The C-PLUG is taken
from the previous device and inserted in the new device. The first time it is started up, the
replacement device has the same configuration as the previous device except for the device-
specific MAC address set by the vendor.
34
LED status
Off
On
LED status
Off
On
Meaning
Port operating in half duplex mode
Port operating in full duplex mode
Meaning
Port is not monitored.
If no link was established at the port the signaling contact
does not indicate an error.
Port is monitored.
If no link was established at the port the signaling contact
indicates an error.
Operating Instructions, 04/2018, C79000-G8976-C442-04