15.6 Details of Control Registers
Address
0x5000
CT_CTL
0x5001
CT_CNT
0x5002
CT_IMSK
0x5003
CT_IFLG
The following describes each clock timer register. These are all 8-bit registers.
Note: When setting the registers, be sure to write a 0, and not a 1, for all "reserved bits."
S1C17704 TECHNICAL MANUAL
Table 15.6.1 List of Clock Timer Registers
Register name
Clock Timer Control Register
Clock Timer Counter Register
Clock Timer Interrupt Mask Register
Clock Timer Interrupt Flag Register
Resets and starts/stops the timer.
Counter data
Enables/disables interrupt.
Indicates/resets interrupt occurrence status.
EPSON
15 CLOCK TIMER (CT)
Function
15-7