Ricoh A250 Service Manual page 844

Hide thumbs Also See for A250:
Table of Contents

Advertisement

Tech Service Bulletin No. A250/B001 – 051 Reissue
Page 2 of 2
12. Remove the 2 connectors for the Cassette Sensors.
13. Remove the LD Unit (Refer to SM pg 6-15).
14. Disconnect the Fusing Unit connector harness from the PSU.
15. Disconnect the 2 connectors on each of the Right door switches.
16. Remove the 8 Registration Frame screws
17. Re-assemble the New Registration Frame.
18. Re-install the Registration Frame to the Copier.
19. Re-assemble all the components to the Copier.
20. Re-install the By-Pass tray and covers.
21. Test with Trim Pattern (Refer to SM pg 6-40)
PARTS LISTING:
OLD PART NO.
A2501164
A2501166
G0291055
A2502961
AA153420
A2501168
G0291094
A2501156
NEW PART NO.
A2501167
Frame Registration
Shield – Main Frame
Duct Sheet
Pad – 7x25x1.4
Shield – Upper Frame
Shield – Frame Duct
Grounding Plate - Transport
Grounding Plate
DESCRIPTION
REFERENCE
QTY
PAGE
ITEM
1
23
30
1
23
2
1
23
4
2
23
29
1
25
10
1
25
11
1
25
16
1
39
6

Advertisement