Copying (North America Model)
Sampling cycle: 1 second
Soft start setting: 6 cycles
Previous minus Current
-3°C or more
–2°C or –1°C
0
+1°C or +2°C
+3°C or more
Copying (Europe Model)
Sampling cycle: 1 second
Soft start setting: 10 cycles
Previous minus Current
-3°C or more
–2°C or –1°C
0
+1°C or +2°C
+3°C or more
Standby
Sampling cycle: 1 second (Europe model: 3 seconds)
Soft start setting: 6 cycles (Europe model: 20 cycles)
Previous minus Current
-3°C or more
–2°C or –1°C
0
+1°C or +2°C
+3°C or more
SM
–2°C or
-3°C or
more
–1°C
100%
100%
100%
70%
100%
50%
100%
30%
100%
Ratio (%): The proportion of time that the fusing lamp power is on
–2°C or
-3°C or
more
–1°C
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
Ratio (%): The proportion of time that the fusing lamp power is on
–2°C or
-3°C or
more
–1°C
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
Ratio (%): The proportion of time that the fusing lamp power is on
2-61
Current minus Target
+1°C or
0
+2°C
100%
100%
70%
70%
30%
30%
0%
0%
0%
Current minus Target
+1°C or
0
+2°C
100%
100%
100%
100%
100%
100%
100%
Current minus Target
+1°C or
0
+2°C
0%
0%
0%
0%
0%
0%
100%
0%
100%
0%
IMAGE FUSING
+3°C or
more
0%
0%
0%
0%
0%
0%
0%
+3°C or
more
0%
0%
0%
0%
0%
0%
0%
0%
+3°C or
more
0%
0%
0%
0%
0%
A250