SERVICE PROGRAM MODE
Mode No.
Class
Class
1 and 2
3
Fusing Idling
1-103*
Fusing Temp. Adj.
1
(Stand-by)
Fusing Temp. Adj.
1-105*
(Energy Saver Level 2)
2
Fusing Temp. Display
1-106
Fusing Soft Start
Adjustment
Fusing Soft Start
Adjustment
(Stand-by)
1
1-107*
Fusing Soft Start
Adjustment
(Copying)
2
A250
Function
Selects whether fusing idling is done
or not.
Normally disabled in this machine.
However, if fusing is incomplete on
the 1st and 2nd copies, switch it on.
This may occur if the room is cold.
Refer to "Detailed Section
Descriptions - Fusing Temperature
Control" for more details.
Adjusts the fusing temperature for
standby mode.
Adjusts the fusing temperature for
energy saver level 2.
With a lower value, the machine
takes more time to reach the ready
condition.
Displays the fusing temperature.
Press the
(Clear Modes) key to
exit the display.
Adjusts the number of zero-cross
cycles of the fusing lamp ac supply
needed for the fusing lamp power to
reach 100%. Use a higher number if
the customer complains about
sudden power dropouts.
See "Detailed Descriptions - Fusing
Unit" for details on SP1-107.
Models other than European
models
Adjusts the number of zero-cross
cycles of the fusing lamp ac supply
needed for the fusing lamp power to
reach 100% when raising the
temperature to the standby
temperature. Use a higher number if
the customer complains about
sudden power dropouts.
See "Detailed Descriptions - Fusing
Unit" for details on SP1-107.
European model only
Adjusts the number of zero-cross
cycles of the fusing lamp ac supply
needed for the fusing lamp power to
reach 100% when raising the
temperature during copying. Use a
higher number if the customer
complains about sudden power
dropouts.
See "Detailed Descriptions - Fusing
Unit" for details on SP1-107.
European model only
4-6
Settings
0: No
1: Yes
100 ~ 190
1°C/step
180°C
0 ~ 140
1°C/step
80°C
0: 6 times
1: 10 times
2: 20 times
0: 6 times
1: 10 times
2: 20 times
0: 6 times
1: 10 times
2: 20 times
SM