Ricoh A250 Service Manual page 522

Hide thumbs Also See for A250:
Table of Contents

Advertisement

NCU PARAMETERS
Address
6804A1
Acceptable CED detection
frequency upper limit (high byte)
6804A2
Acceptable CED detection
frequency upper limit (low byte)
6804A3
Acceptable CED detection
frequency lower limit (high byte)
6804A4
Acceptable CED detection
frequency lower limit (low byte)
6804A5
CED detection time
6804A6
Acceptable CNG detection
frequency upper limit (high byte)
6804A7
Acceptable CNG detection
frequency upper limit (low byte)
6804A8
Acceptable CNG detection
frequency lower limit (high byte)
6804A9
Acceptable CNG detection
frequency lower limit (low byte)
6804AA
Not used
6804AB
CNG on time
6804AC
CNG off time
Number of CNG cycles required for
6804AD
detection
6804AE
Not used
6804AF
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (high byte)
6804B0
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (low byte)
6804B1
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (high byte)
6804B2
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (low byte)
6804B3
Detection time for 800 Hz AI short
protocol tone
6804B4
PSTN: Tx level from the modem
6804B5
PSTN: 1100 Hz tone transmission
level
6804B6
PSTN: 2100 Hz tone transmission
level
6804B7
PABX: Tx level from the modem
A250
Function
4-60
Unit
BCD (Hz)
If both addresses
contain FF(H), tone
detection is disabled.
BCD (Hz)
If both addresses
contain FF(H), tone
detection is disabled.
20 ms
Factory setting: 200 ms
± 20 ms
BCD (Hz)
If both addresses
contain FF(H), tone
detection is disabled.
BCD (Hz)
If both addresses
contain FF(H), tone
detection is disabled.
Do not change the
setting.
20 ms
Factory setting: 500 ms
20 ms
Factory setting: 200 ms
The data is coded in the
same way as address
680433.
Do not change the
settings.
Hz (BCD)
If both addresses
contain FF(H), tone
detection is disabled.
Hz(BCD)
If both addresses
contain FF(H), tone
detection is disabled.
20 ms
Factory setting: 360 ms
- dBm
Function 06-2
(parameter 01).
- N
- 0.5N
6804B4
6804B5
See Note 7.
- N
- 0.5N
6804B4
6804B6
See Note 7.
- dBm
Remarks
(dB)
(dB)
SM