NCU PARAMETERS
Address
680433
Busy tone signal state time tolerance for all ranges, and number of cycles
required for detection (a setting of 4 cycles means that ON-OFF-ON or OFF-
ON-OFF must be detected twice).
Tolerance (±)
Bit
Bits 7, 6, 5, 4 - number of cycles required for cadence detection
680434
International dial tone frequency
upper limit (high byte)
680435
International dial tone frequency
upper limit (low byte)
680436
International dial tone frequency
lower limit (high byte)
680437
International dial tone frequency
lower limit (low byte)
680438
International dial tone detection
time
680439
International dial tone reset time
(LOW)
68043A
International dial tone reset time
(HIGH)
68043B
International dial tone continuous
tone time
68043C
International dial tone permissible
drop time
68043D
International dial wait interval
(HIGH)
68043E
International dial wait interval
(LOW)
68043F
Country dial tone upper frequency
limit (HIGH)
680440
Country dial tone upper frequency
limit (LOW)
680441
Country dial tone lower frequency
limit (HIGH)
680442
Country dial tone lower frequency
limit (LOW)
A250
Function
1
0
0
0
75%
0
1
50%
1
0
25%
1
1
12.5%
Unit
Bits 2 and 3 must always
be kept at 0.
Hz (BCD)
Hz (BCD)
20 ms
Hz (BCD)
4-56
Remarks
If both addresses
contain FF(H), tone
detection is disabled.
If both addresses
contain FF(H), tone
detection is disabled.
If 680438 contains FF,
the machine pauses for
the pause time (68043D
/ 68043E).
Belgium: See Note 2.
If both addresses
contain FF(H), tone
detection is disabled.
If both addresses
contain FF(H), tone
detection is disabled.