[E]
[G]
[D]
5. Disconnect the hot roller stripper pawl springs (see Hot Roller Stripper Pawl
Removal, section 6.5.5.)
6. Remove the hot roller grounding terminal [D] (1 screw).
7. Remove the two screws securing the fusing lamp terminals [E].
8. Replace the hot roller [F].
9. Replace the fusing lamp [G].
10. Replace the thermofuse [H] (2 screws).
NOTE: 1) Do not touch the hot roller with your bare hands.
2) Do not touch the fusing lamp with your bare hands.
SM
[F]
[H]
6-19