Mode No.
Class
Class
1 and 2
3
Gradation Type
2-905*
Transfer Roller Cleaning
2-910
Polygon Motor Idling
Time
2-915*
Printer Main
Magnification
2-998*
Main Scan Magnification
4-008*
Leading Edge
Registration
4-010*
SM
SERVICE PROGRAM MODE
Function
This is for the designer's test
purposes.
Do not change the value.
Determines how often the transfer
roller is cleaned.
0: The machine cleans the transfer
roller every 10 copies (it waits for
the job to finish).
1: The machine cleans the transfer
roller after every job.
Selects the polygon motor idling
time.
If the user sets original, touches a
key, or opens the platen cover/DF,
the polygon motor starts idling to
make a faster first copy. However,
with the default (25 s), the motor
stops if the user does nothing for 25
s, and stops 25 s after the end of a
job.
If set at "0", the polygon motor never
turns off during stand-by. However,
when the machine goes into energy
saver mode, the polygon motor turns
off regardless of this timer.
Adjusts the magnification in the main
scan direction for the printer.
Use the
key to toggle between +
and - before entering the value. The
specification is ± 0.5%. See
"Replacement and Adjustment -
Copy Adjustment" for details.
Adjusts the magnification in the main
scan direction for scanning.
Use the
key to toggle between +
and - before entering the value. The
specification is ± 0.5%. See
"Replacement and Adjustment -
Copy Adjustment" for details.
Adjusts the leading edge registration
for scanning in platen mode.
(–): The image moves in the
direction of the leading edge.
Use the
key to toggle between +
and - before entering the value. The
specification is 2 ± 1.5 mm. See
"Replacement and Adjustment -
Copy Adjustment" for details.
4-13
Settings
0: No
1: Yes
0: Non
1: 15 sec
2: 25 sec
– 0.5 ~ + 0.5
0.1 %/step
0.0%
– 1.0 ~ + 1.0
0.1 %/step
0.0%
– 2.0 ~ + 9.0
0.1 mm/step
0.0 mm