Ricoh A250 Service Manual page 540

Hide thumbs Also See for A250:
Table of Contents

Advertisement

SERVICE RAM ADDRESSES
6803AB to 6803AD(H) - Effective term of automatic service calls
Year: last two digits of the year (BCD)
Month: 01 through 12 (BCD)
Day: 01 through 31 (BCD)
680400 to 6804E0(H) - NCU parameters (Refer to section 4.3 for details)
680DC8 to 680DEF(H) - SC codes NOT for automatic service call
If the fax unit receives a copier engine SC code other than those programmed in
these addresses, the fax unit sends an automatic service call report to the
programmed service station.
Six SC codes have already been programmed at default, as shown in the table
below. Fourteen more SC codes can be programmed, if required (if an address
contains FF(H), a code is not programmed in it).
Program a SC code in four-digit BCD format as shown in the example below.
Example 1: SC code '192'
Address (High) - 01 (BCD)
Address (Low) - 92 (BCD)
Wildcard characters "a" or "A" can be used to specify a series of SC codes.
Example 2: SC code '900 to 999"
Address (High) – 09 (BCD)
Address (Low) – aa or AA (Hex)
Example 3: SC code '330 to 339"
Address (High) – 03 (BCD)
Address (Low) – 3a or 3A (Hex)
- Default settings -
High Address (H)
680DC8
680DCA
680DCC
680DCE
680DD0
680DD2
680DD4
to
680DEE
68849C to 68889B(H) - Dedicated tx parameters for Quick Dial 01 - 32.
There are 32 bytes for each Quick Dial. Only the 23rd to 32nd bytes are used.
6884B2 to 6884BB(H) - Dedicated tx parameters for Quick 01
6884D2 to 6884DB(H) - Dedicated tx parameters for Quick 02
6884F2 to 6884FB(H) - Dedicated tx parameters for Quick 03
688892 to 68889B(H) - Dedicated tx parameters for Quick 32
A250
Parameters
Data (BCD)
Low Address (L)
03
680DC9
03
680DCB
03
680DCD
05
680DCF
06
680DD1
09
680DD3
680DD5
FF(H)
680DEF
Data (BCD)
29
61
65
48
30
AA
to
FF(H)
4-78
Address (H)
6803AB
6803AC
6803AD
SC code
329
361
365
548
630
900 to 999
Not Programmed