Ricoh A250 Service Manual page 513

Hide thumbs Also See for A250:
Table of Contents

Advertisement

G3 Switch 0A
No
FUNCTION
0
Maximum allowable carrier
1
drop during image data
reception
Bit 1
Bit 0
0
0
0
1
1
0
1
1
2-3 Not used
4
Maximum allowable frame
interval during image data
reception.
0: 5 s 1: 13 s
5
Not used
6
Reconstruction time for the
first line in receive mode
0: 6 s 1: 12 s
7
Not used
G3 Switch 0B
No
FUNCTION
0
Protocol requirements:
Europe
0: Disabled 1: Enabled
1
Protocol requirements: Spain
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3
Protocol requirements: France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
5
PTT requirements: France
0: Disabled 1: Enabled
6
Not used
7
DTS requirements : Germany
0: Disabled 1: Enabled
SM
These bits set the acceptable modem carrier drop
time.
Try using a longer setting if error code 0-22 is
Value (ms)
frequent.
200
400
800
Not used
Do not change the settings.
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
Do not change the settings.
When the sending terminal is controlled by a
computer, there may be a delay in receiving page
data after the local machine accepts set-up data
and sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set this
bit to 1 to give the sending machine more time to
send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
Do not change the settings.
The machine does not automatically reset these
bits for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
Do not change the settings.
Change this bit manually if required.
4-51
BIT SWITCHES
COMMENTS
COMMENTS
A250