BIT SWITCHES
Communication Switch 14
No
FUNCTION
0
Inch-to-mm conversion during
transmission
0: Disabled 1: Enabled
1-5 Not used
6
Available unit of resolution in
7
which fax messages are
received
Bit 7
Bit 6
0
0
0
1
1
0
1
1
Communication Switch 15 - Not used (do not change the settings)
Communication Switch 16
No
FUNCTION
0-1 Not used
2
Optional ISDN unit
0: Not installed
1: Installed
3-5 Not used
6
G4 Dual communication
0: Enabled
1: Disabled
G4: Europe model only
7
Not used
A250
0: In immediate transmission, data scanned in
inch format are transmitted without conversion.
In memory transmission, data stored in the SAF
memory in mm format are transmitted without
conversion.
Note: When storing the scanned data into SAF
memory, the fax unit always converts the data
into mm format.
1: The machine converts the scanned data or
stored data in the SAF memory to the format
which was specified in the set-up protocol
(DIS/NSF) before transmission.
Do not change the factory settings.
For the best performance, do not change the
factory settings.
Unit
The setting determined by these bits is informed
mm
to the transmitting terminal in the pre-message
inch
protocol exchange (in the DIS/NSF frames).
mm and inch
(default)
Not used
Do not change the settings.
Change this bit to 1 when installing the optional
ISDN unit.
G4: Europe model only
Do not change the settings.
1: The machine uses only one B channel for
communication. This enables a customer to
occupy another B channel for other purposes
such as internet communication.
Do not change the settings.
COMMENTS
COMMENTS
4-42
SM

Advertisement