BIT SWITCHES
System Switch 16
No
FUNCTION
0
Parallel Broadcasting
0: Disabled
1: Enabled
1-7 Not used
System Switch 17 - Not used (do not change the settings)
System Switch 18 - Not used (do not change the settings)
System Switch 19
No
FUNCTION
0
Key acknowledgement tone
to
volume adjustment
2
000 (Min.: OFF)-111 (Max.)
Default setting – 011
3-6 Not used
7
Special Original mode
0: Disabled
1: Enabled
System Switch 1A - Not used (do not change the settings)
System Switch 1B - Not used (do not change the settings)
A250
1: When the G4 unit is installed, the machine
sends messages simultaneously using both
available ports (PSTN/ISDN) for broadcasting, if
the job contains both PSTN and ISDN
destinations.
This is available for the European model only.
Do not change the settings.
COMMENTS
This controls the volume of this tone when the
machine is in fax mode (it has no effect on the tone
when the machine is in copier or printer mode).
Do not change the settings.
1: If the customer frequently wishes to transmit a
form or letterhead which has a colored or printed
background, change this bit to "1". "Special
Original" can be selected in addition to the "Text",
"Text/Photo" and "Photo" modes.
When this mode is selected, the "Text/Photo" and
"Photo" LEDs are both lit.
Cross reference
Y
Type of special original mode – Scanner switch
00 bit 0.