Communication Switch 02
No
FUNCTION
3
Hang-up decision when a
negative code (RTN or PIN) is
received during G3 immediate
transmission
0: No hang-up, 1: Hang-up
4-6 Not used
7
Method of total error rate
calculation
0: Normal method
1: French PTT requirement
Communication Switch 03
No
FUNCTION
0
Maximum number of page
to
retransmissions in a G3
7
memory transmission
Communication Switch 04 - Not used (do not change the settings)
Communication Switch 05 - Not used (do not change the settings)
Communication Switch 06
No
FUNCTION
0
Dialing requirements:
Germany
0: Disabled 1: Enabled
1
Dialing requirements: Austria
0: Disabled 1: Enabled
2
Dialing requirements: Norway
0: Disabled 1: Enabled
3
Dialing requirements:
Denmark
0: Disabled 1: Enabled
4
Dialing requirements: France
0: Disabled 1: Enabled
5
Dialing requirements:
Switzerland
0: Disabled 1: Enabled
6
Not used
7
Carrier drop display
0: Disabled 1: Enabled
SM
COMMENTS
0: The next page will be sent even if RTN or PIN
is received.
1: The machine will send DCN and hang up if it
receives RTN or PIN.
This bit is ignored for memory transmissions or if
ECM is being used.
Do not change the settings.
0: Error rate is calculated by dividing the number
of total lines by the number of error lines.
1: Error rate is calculated by dividing the number
of total plus error lines by the number of error
lines.
COMMENTS
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
COMMENTS
These switches are automatically set to the
settings required by each country after the
country code (System Switch 0F) is programmed.
Do not change the settings.
This is an European PTT requirement.
This bit is available only for the European models.
4-39