G4 Communication Parameters
Compression
MMR: MMR compression
mode
MR: MR compression
MH: MH compression
Resolution
21: Standard (200 x 100 dpi)
22: Detail (200 x 200 dpi)
44: Superfine (400 x 400 dpi)
Width and
A4: A4 (8.3"), no reduction
reduction
B4: B4 (10.1"), no reduction
A3: A3 (11.7"), no reduction
Transfer
T: Transfer
- : Other
Confidential
C: Confidential
- : Other
Other parameters
The following information is shown in 6-bit format. Bit 1 is the first
bit from the left, and bit 6 is at the right end.
Bit 1 - Smoothing
Bit 2 - CIL printing
Bit 3 - Not used
Bit 4 - mm/inch conversion
Bit 5 - Engine type
Bit 6 - Document resolution unit
System Switch 01
No
FUNCTION
0
Automatic Service Call at PM
0: Disabled
1: Enabled
1-7 Not used
SM
(Smoothing is disabled in halftone mode.)
This bit switch determines whether the machine
will send an Auto Service Call to the service
station when it is time for PM.
Cross reference
Auto service calls: Section 2.1
Do not change the settings.
4-15
BIT SWITCHES
0: Off, 1: On
0: On, 1: Off
0: Off, 1: On
0: mm, 1: inches
0: mm, 1: inches
COMMENTS
A250