Tech Service Bulletin No. A250/B001 – 035
Page 2 of 3
PROCEDURE:
The procedure for attaching the two Mylars in the field is as follows. Please refer to illustration C.
1. Clean the attachment surface with alcohol.
2. Peel off the double-sided tape of the Mylars.
3. Line up the Mylars with surface [A]. Make sure that the cut corner [B] is facing down.
4. Line up the folded line [C] of the Mylars with the folded edge [D] of the Tray.
5. Attach the strip of Mylar to both surfaces by pressing down firmly on the double-sided tape area.
Mylar
Illustration B
[A]
Illustration C
[C]
[D]
[B]
Continued...