SERVICE PROGRAM MODE
Class
Class
1 and 2
3
5-906*
5-907
5-908*
5-911*
5-912*
5-913
5-914*
5-925
A250
Mode No.
Exhaust Fan Control
Timer
Plug & Play Setting
Maintenance LED
Display
APS A4/LT Sideways
Priority
Maintenance Alarm
Interval
UP Mode Data Reset
Printer Counter Display
Serial Number Display
Function
Inputs the fan control timer for
energy saver mode.
The fan slows down after this time
has passed since the end of a job.
The fan stops after this time has
passed since any of the following
conditions occurred:
After entering sleep mode
(fax/printer installed)
After entering an SC condition.
Selects the brand name and the production name for
the Plug and Play function of Windows 95/98.
These are registered in the NVRAM. If the NVRAM is
defective, these names should be registered again.
Press down the "Photo mode" key and the "OK" key
or ! key at the same time to register the setting. If
the setting was successful, the beeper will sound 5
times. If it failed, the beeper will sound only twice.
Selects whether the maintenance
LED blinks when the PM interval
expires.
When installing the machine, if the
customer requires that the
maintenance LED blinks, select
"Yes". The PM alarm interval is set
with SP5-912.
Specifies whether the machine
selects LT sideways paper if the
original is A4.
In inch models, if "Yes" is selected,
LT sideways is selected
automatically when the APS sensors
detect an A4 sideways original.
In mm models, if "Yes" is selected,
A4 sideways is selected
automatically when the APS sensors
detect an LT sideways original.
Inputs the PM alarm interval.
When the machine reaches the
value, the Maintenance LED will light
to inform the user. The value is used
SP5-908.
Resets the user tool data.
Except for the user codes, key
operator code, and key operator
printer counter.
Selects whether the printer counter
is displayed in the LCD or not.
If this is "0", it does not display or
print out in the counter print out.
Displays the serial number.
4-30
Rev. 12/99
Settings
30 ~ 120
1 s/step
30 s
0: No
1: Yes
0: No
1: Yes
1 ~ 255
1 k
sheets/step
100 k sheets
0: No
1: Yes
0: No
1: Yes