System Switch 04
No
FUNCTION
5
Memory file transfer operation
0: User level
1: Service level
6
G3 CSI/G4 Terminal ID
programming level
0: User level
1: Service level
7
Telephone line type
programming mode
0: User level
1: Service level
System Switch 05
No
FUNCTION
0-1 Not used
2
Display of both RTI and CSI
on the LCD
0: Disabled
1: Enabled
3-7 Not used
System Switch 06
No
FUNCTION
0
Margin setting for Create
to
Margin Transmission
7
SM
COMMENTS
If the machine is unable to print fax messages
due to a mechanical problem, change this bit to 0
to transfer all messages in the memory (including
confidential rx messages) to an another terminal.
Always reset this bit to 1 after transfer. However,
this bit can be left at 0, if the customer's key-
operators want to transfer the files themselves.
Procedure
1. Enter service mode and change this bit to 0.
2. Exit the service mode.
3. Enter the key-operator mode, and select 'Key-
operator settings'.
4. Choose '03' and specify a destination for the
machine to transfer all the files to.
5. Press 'Start'.
6. After the machine transfers the memory files,
enter the service mode and reset this bit to 1.
Otherwise, anybody who knows how to enter the
key-operator mode can transfer confidential
messages.
1: The CSI and Terminal ID can only be
programmed by a technician (in the user tools).
The Terminal ID can only be programmed if a
Group 4 option is installed.
1: Telephone line type selection (choosing tone
dial or pulse dial) can only be programmed by a
technician (in the user tools).
COMMENTS
Do not change the settings.
1: An RTI will be displayed until phase B of the
protocol sequence, and a CSI will be displayed
after phase C.
Do not change the settings.
COMMENTS
71 to 99 (BCD) %. This setting determines the
reduction ratio when the user uses the Create
Margin Transmission option.
Default setting:1001 0011 (93%)