Ricoh A250 Service Manual page 157

Hide thumbs Also See for A250:
Table of Contents

Advertisement

OPTICS ANTI-CONDENSATION HEATER INSTALLATION (OPTION)
3.10 OPTICS ANTI-CONDENSATION HEATER
INSTALLATION (OPTION)
1. Remove the exposure glass. (See Exposure Glass Removal, section 6.2.1.)
2. Remove the rear cover. (See Rear Cover Removal, section 6.1.1.)
3. Pass the connector [A] through the opening [B].
4. Install the optics anti-condensation heater [C], as shown.
5. Join the connectors [A, D].
6. Re-install the exposure glass.
SM
[C]
3-33
[A]
[B]
[D]