ERROR CODES
Code
Meaning
0-87
The control channel started
after an unsuccessful
primary channel.
0-88
The line was disconnected
because PPR was
transmitted/received 9
(default) times within the
same ECM frame.
2-10
The modem cannot enter
tx mode
2-11
Only one V.21 connection
flag was received
2-12
Modem clock irregularity
2-13
Modem initialization error
2-20
Abnormal coding/decoding
(cpu not ready)
2-23
JBIG compression or
reconstruction error
2-24
JBIG ASIC error
2-25
JBIG data reconstruction
error (BIH error)
2-26
JBIG data reconstruction
error (Float marker error)
2-27
JBIG data reconstruction
error (End marker error)
JBIG data reconstruction
2-28
error (Timeout)
2-50
The machine resets itself
for a fatal FCU system
error
2-51
The machine resets itself
because of a fatal
communication error
3-00
G4 interface board reset
3-10
Disconnection during ISDN
G3 communication
3-11
Disconnection during ISDN
G4 communication
3-20
A CSA signal was received
during ISDN G4
communication
A250
Suggested Cause/Action
• The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
• This does not result in an error communication.
• Try using a lower data rate at the start.
• Try adjusting the cable equalizer setting.
• Replace the FCU.
• Replace the FCU.
• Replace the FCU.
• Turn off the machine, then turn it back on.
• Update the modem ROM.
• Replace the FCU.
• Replace the FCU.
• Turn off the machine, then turn it back on.
• Replace the EXFUNC board if the error is
frequent.
• Turn off the machine, then turn it back on.
• Replace the EXFUNC board if the error is
frequent.
• JBIG data error
• Check the sender's JBIG function.
• Update the FCU ROM.
• If this is frequent, update the ROM, or replace
the FCU.
• If this is frequent, update the ROM, or replace
the FCU.
• Replace the G4 interface board or FCU.
• Check the other terminal and the ISDN line.
• The other terminal may have dialed a wrong
number.
• Check the other terminal and the ISDN line.
• The operator at the other terminal may have
interrupted the communication.