Hardware Reset (RS)
Table 3−5. Registers After Reset (Continued)
3-24
Register
Bit(s)
P
all
PC
all
RPC
all
SP
all
ST0
0: SXM
1: OVM
2: TC
3: C
4: Z
5: N
6: V
7−9: PM
10−15: OVC
Note:
The registers listed in this table are introduced in section 2.2, CPU Registers, on page
2-4.
Value After Reset
0000 0000
16
3F FFC0
16
0000
16
SP = 0x400
0
0
0
0
0
0
0
000
2
00 0000
2
Comments
PC is loaded with the
reset interrupt vector at
program-space address
00 0000
or 3F FFC0
16
16
SP points to address
0400.
Sign extension is
suppressed.
Overflow mode is off.
The product shift mode is
set to left-shift-by-1.
.