sntp unicast-server

Description
With this command, you configure an SNTP unicast server.
Requirement
● The addressing mode of the SNTP client is configured as "unicast".
● You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp unicast-server {ipv4 <ucast_addr> | fqdn-name <FQDN(100)>} [port<1025-
36564>][poll<seconds(16-16284)>]
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN(100)
port
poll
seconds
Result
The SNTP unicast server is configured.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
command.
Description
Keyword for an IP address
Value for an IPv4 unicast address
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
UDP port of the time server
Keyword for the time after which the
time of day is requested again
Value for the time in seconds
System time
5.3 SNTP client
show sntp
Range of values / note
-
Enter a valid IPv4 unicast ad-
dress.
-
Maximum of 100 characters
1025 ... 36564
Default: 123
-
16 ... 16284