Siemens SCALANCE W760 Configuration Manual page 243

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
spanning-tree {cost <0-200000000>|disable|
The parameters have the following meaning:
Parameter
cost
disable
link-type
portfast
port-priority
Note
Configure multiple properties
With each call of the command, you can configure precisely one property.
If you want to configure several properties, call the command several times.
Result
The selected property is configured.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
link-type{point-to-point|shared}|portfast|
port-priority<0-240>}
Description
Keyword
Describes the costs of the port for
calculating the lowest cost path.
disables the interface for spanning tree -
Connection status of the following
network segment
Enables the PortFast function
Priority of the interface
Network structures
6.3 Spanning Tree
Range of values / note
0 ... 200000000
Default:
if dynamic calculation of the path
costs is not enabled:
200000 for physical interfaces
199999 for port channels
Default:
The spanning tree function is
enabled on the interface
point-to-point
shared
Default:
point-to-point
The connection is configured
as
full-duplex
shared
in all other cases
-
Default: disabled
0 ... 240 in steps of 16
Default: 128