Syntax
Call up the command with the following parameters:
wlan frequency band { all | 2.4 | 5 }
The parameters have the following meaning:
Parameters
all
2.4
5
Result
The frequency band for the WLAN interface is specified.
Further notes
You display the setting with the
6.1.5.39

wlan guard interval (access point)

Description
With this command, you specify the send pause that must be kept to between two
transferred OFDM symbols.
Note
This command is available only in access point mode.
Requirement
● The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
Description
Both frequency bands are used.
Frequency band 2.4 GHz
Frequency band 5.2 (4.9; 5.6; 5.8) GHz
show wlan basic <wlan 0/X>
Network structures
Default setting
WLAN1: 2.4 GHz
command.
6.1 WLAN