Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
mac-address-table aging-time <seconds(10-1000000)>
The parameter has the following meaning:
Parameters
seconds
At system start or when using the
following defaults apply:
● The function is configured to 300 seconds.
Result
The value of the aging of a dynamically learned entry is configured.
Further notes
You can reset the setting to the default with the
You display the setting with the
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
Description
Life of the entry in seconds
restart
show mac-address-table aging-time
command with the option
no mac-address-table aging-time
Load control
8.1 Dynamic MAC aging
Range of values
10 ... 1000000
or
, the
memory
factory
command.
command.