Wlan Ampdu - Siemens SCALANCE W760 Configuration Manual

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

6.1.5.5

wlan ampdu

Description
With this command, you enable the sending of AMPDU data packets. The function is
enabled as default.
Requirement
● The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call the command without parameter assignment:
wlan ampdu
Result
The sending of AMPDU data packets is enabled.
Further notes
You display the setting with the
You disable the function with the
See also
no wlan ampdu (Page 146)
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
show wlan advanced-11n <wlan 0/X>
command.
no wlan ampdu
Network structures
6.1 WLAN
command.
145