Diagnostics; Show Authlog - Siemens SCALANCE W760 Configuration Manual

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

Diagnostics

The monitoring of the system and error diagnostics are handled in different ways:
● Events and faults handling:
Predefined events generate a message. These messages can be distributed in different
ways:
– Entry in the local log
– Transfer to the Syslog server
– Sending as e-mail
– Sending as SNMP trap
● Syslog:
Configures the transfer to the Syslog server
● Port mirroring:
Mirroring of ports to analyze the data stream without disturbing operation
11.1
Diagnostics
In events and faults handling, you set the events whose messages will be distributed in one
of the available ways.
You configure the monitoring of certain system events and power supply and physical
interfaces in the Events configuration mode.
11.1.1

show authlog

Description
With this command, you show the information about successful or failed authentication
attempts.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
or
cli#
11
403

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720

Table of Contents