Snmp Access - Siemens SCALANCE W760 Configuration Manual

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
snmp agent version{v3only|all}
The parameters have the following meaning:
Parameter
v3only
all
Result
The setting is configured.
7.4.2.4

snmp access

Description
With this command, you configure the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName>{v1|v2c|v3{auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
GroupName
-
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
Description
only SNMPv3 queries are processed
all SNMP queries are processed
Description
Name of the group to which access is
configured
Selects the version of the protocol
used
Network protocols
7.4 SNMP
Range of values / note
-
Default: all
Range of values / note
max. 32 characters
v1
v2c
v3
309