Network protocols
7.5 SMTP client
7.5.4.1

smtp-server

Description
With this command, you configure an entry for an SMTP server.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-server {ipv4 <ucast_addr> | fqdn-name <FQDN(100)>} <receiver mail-address>
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN(100)
receiver mail-
address
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 23)".
Result
An entry for the SMTP server is configured.
Further notes
You delete an SMTP server entry with the
332
Description
Keyword for an IP address
Value for an IPv4 unicast address
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Name of the recipient
no smtp-server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Note on the range if values
-
Enter a valid IPv4 unicast ad-
dress.
-
Maximum of 100 characters
max. 100 characters
command.