Security and authentication
10.2 WLAN
10.2.6.9

no vap communication with own-vap (access point)

Description
With this command, you specify that clients logged on to the same SSID of an access point
cannot communicate with each other.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with own-vap
Result
The communication option on the same SSID of an access point is disabled.
Further notes
You display the settings with the
You enable the function with the
See also
vap communication with own-vap (access point) (Page 395)
396
show wlan security <vapX 0/Y>
vap communication with own-vap
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
command.
command.