Diagnostics
11.2 Syslog client
11.2.2.1

syslogserver

Description
With this command, you configure the Syslog server address.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
syslogserver {ipv4 <ucast_addr> | fqdn-name <FQDN(100)>} [<port(1-65535)>]
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN(100)
port
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 23)".
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for the Syslog server are configured.
Further notes
You disable the setting with the
You can display the status of this function and other information with the
command.
424
Description
Keyword for an IP address
Syslog server IPv4 Address
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Serverport
no syslogserver
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
-
Enter a valid IPv4 address.
-
Maximum of 100 characters
1 .. 65535
Default: 514
command.
Configuration Manual, 11/2014, C79000-G8976-C351-03