Client Config - Siemens SCALANCE W760 Configuration Manual

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

Result
The entry has been made in the logbook.
11.1.14.2

client config

Description
With this command, you enable one of the clients that processes or forwards the messages
of the device.
The following clients are available:
syslog
trap
email
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
client config {syslog|trap|email|all}
The parameters have the following meaning:
Parameter
syslog
trap
email
all
Result
The function of the client selected for the transfer is enabled.
Further notes
You display the status of the events and the clients with the
You disable a client with the
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
: sends the messages to the Syslog server
: sends the messages as SNMP trap to a configured recipient
: sends the messages as e-mail
Description
Enables the client that sends the messages to the Syslog server
Enables the client that sends the SNMP traps
Enables the client that sends the e-mails
Enables all clients at once
no client config
show events config
command.