Severity - Siemens SCALANCE W760 Configuration Manual

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

Diagnostics
11.1 Diagnostics
Parameter
trap
faults
all
Result
The setting deciding which messages of the device are not stored or forwarded is
configured.
Further notes
You display the status of the events and the clients with the
You configure which of the various message types of the device will be stored or forwarded
with the
11.1.14.6

severity

Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog } { info | warning | critical }
The parameters have the following meaning:
Parameter
mail
log
syslog
418
Description
Client that sends the SNMP traps
The device triggers an error. The error LED lights up.
All clients at once
command.
event config
Description
Specifies the threshold value for send-
ing system event messages by e-mail.
Specifies the threshold value for enter-
ing system event messages in the log
table.
Specifies the threshold value for enter-
ing system event messages in the
Syslog file.
show events config
Range of values / note
-
-
-
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
command.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720

Table of Contents