Wlan Signal-Recorder Start Sample_Number (Client) - Siemens SCALANCE W760 Configuration Manual

Industrial wireless lan
Hide thumbs Also See for SCALANCE W760:
Table of Contents

Advertisement

Functions specific to SCALANCE
4.2 Signal recorder
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
show wlan signal-recorder <wlan 0/X>
The parameter has the following meaning:
Parameter
wlan 0/X
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 23)".
Result
The status of the signal recorder and the recording are displayed.
● If the recording has started, the configured interval and the current number of recorded
measured values are displayed.
● If the recording has stopped, the configured interval and the number of recorded
measured values are displayed.
4.2.2

wlan signal-recorder start sample_number (Client)

Description
With this command, you configure and start recording with the signal recorder. The
measured values are logged in files. On completion of the recording, the files can be
downloaded as a zip file using http or tftp. The values are stored every 10 minutes. The file
contains all values since the start of the recording.
Note
This command is only available in the client mode.
86
or
cli#
Description
WLAN interface
Values or range of values
Enter a valid interface.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720

Table of Contents