Security Configuration Command Set
Configuring Flow Setup Throttling (FST)

14.3.15.11 set flowlimit notification

Use this command to enable or disable flow limit notification, or to set a notification interval. When
enabled, this allows ports configured with a "trap" action to send an SNMP trap message when a
specified flow limit is reached. For information on using the set flowlimit limit command to
configure a trap action on a port, refer to
set flowlimit notification {disable | enable | interval}
Syntax Description
disable | enable
interval
Command Type
Switch command.
Command Mode
Read-Write.
Command Defaults
None.
Example
This example shows how to enable the flow limit notification function:
Matrix(rw)->set flowlimit notification enable
14-204 Matrix DFE-Platinum and Diamond Series Configuration Guide
Section
14.3.15.3.
Disables or enables SNMP notification.
Specifies a notification interval (in seconds) for SNMP trap
messages. Valid values are 0 - 4294967295.