Getstno (Acquiring Starting Word Number Of Specified Slot) - Panasonic FP7 Series Command Reference Manual

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

13.11 GETSTNO (Acquiring Starting Word Number of Specified Slot)

13.11 GETSTNO (Acquiring Starting Word Number of Specified Slot)
Ladder diagram
List of operands
Operand
Description
S
Specify the starting address of the device that stores the slot number or a constant.
D
Specify the starting address of a readout destination device.
Devices that can be specified (indicated by ●)
Operan
d
W
W
X
Y
S
D
Outline of operation
● This instruction reads the starting word number of the slot specified by [S] and sets it in [D].
Precautions for programming
● An operation error occurs when a slot number without unit registration is specified when an
I/O map has been registered.
● An operation error occurs when the number of a slot in which no unit is installed is specified
when no I/O map has been registered.
Flag operations
Name
Description
To be set in case of out-of-range values in indirect access (index modification).
To be set when an out-of-range value is specified for [S] (slot number).
SR7
To be set when a slot number (S) without unit registration is specified when an I/O map has been
SR8
registered.
(ER)
To be set when a slot number (S) without an installed unit is specified when no I/O map has been
registered.
13-18
16-Bit device:
W
W
W
S
D
L
R
L
S
D
T
D
32-Bit
device:
TS
TE
U
W
WI
IX
C
C
M
O
S
E
Real
St
Integer
numbe
rin
r
g
D
K
H
SF
" "
F
WUME-FP7CPUPGR-12
Index
modifie
r

Advertisement

Table of Contents
loading

Table of Contents