Panasonic FP7 Series Command Reference Manual page 415

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

Processing
Example 1) Operation unit: 16 bits (US)
Output bit 3 of the pre-operation data to CY. Output CY of the pre-operation data to bit 12
Example 2) Operation unit: 32 bits (UL)
Output bit 7 of the pre-operation data to CY. Output CY of the pre-operation data to bit 24
Flag operations
Name
SR7
SR8
(ER)
SR9
(CY)
WUME-FP7CPUPGR-12
8.13 RCR (Right Rotation of Data with Carry-Flag Data)
Description
To be set in the case of out-of-range in indirect access (index modification).
(Rotation amount -1) bits of the pre-operation data are output.
When the operation unit is 16 bits (US), if [n] is either 0 or a multiple of 17, the rotation
amount is regarded as 0, and no change occurs.
When the operation unit is 32 bits (UL), if [n] is either 0 or a multiple of 33, the rotation
amount is regarded as 0, and no change occurs.
8-27