Panasonic FP7 Series Command Reference Manual page 959

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

Setting item Settings
REN
Rename
method
(Note 1)
Input each operation setting parameter separated by a comma ",".
(Note 2)
Specify the operation setting parameters in the order of the above table. The order of keywords cannot
be changed.
(Note 3)
Upper and lower case characters can be used for specifying keywords.
Setting example
Exam
S2
"SV0,MODE=OVW"
ple 1
Settings
FTP server: 0, Transfer operation: Overwrite method
Exam
S2
"SV3,MODE=REN"
ple 2
Settings
FTP server: 2, Transfer operation: Rename method
Exam
S2
"SV3"
ple 3
Settings
FTP server: 3, Transfer operation: (Omitted)
Operand [S3] setting
● Specify the starting address of the device area that stores the string data that indicates a
destination folder name, or a character constant.
● A destination folder name should be specified within 256 one-byte characters.
Setting item
Settings
Destination folder
S3
name
(Note 1)
When the specified destination folder does not exist, the folder is automatically created with up to eight
hierarchies.
(Note 2)
Specify a folder name from the home directory of a user which logs in FTP servers with a relative path.
Flag operations
Name
Description
To be set when the slot number [S1] specified with UNITSEL is not 100 (built-in ET-LAN).
To be set when the request active relay of the FTPc logging/trace control relay for a specified
number is 1: Requesting.
SR7
To be set when the logging/trace condition of a specified LOGn number is not registered.
SR8
To be set when an out-of-range value is specified for parameters.
(ER)
To be set when executed in an interrupt program.
Set when the number of characters for operand specifying character constant exceeds 256.
To be set when an unset FTP server is specified.
WUME-FP7CPUPGR-12
17.13 FTPcLOG (FTP Client Logging/Trace Transfer Setting)
Performs transfer files with temporary file names, and renames them to
specified file names after the success of the transfer. The successful
completion of file transfer can be confirmed by checking the file names
specified by the logging/trace setting.
The processing time is longer than that of the overwrite method.
Specify the starting address of the device area that
stores the string data that indicates a destination folder
name, or a character constant.
Setting
range
Maximum
256 one-byte
characters
17-71