Httpcctl (Http Client Transfer Control) - Panasonic FP7 Series Command Reference Manual

Cpu unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

17.19 HTTPcCTL (HTTP Client Transfer Control)

17.19 HTTPcCTL (HTTP Client Transfer Control)
Ladder diagram
(Note 1)
The above figure shows the case that S1=U100 (built-in ET-LAN in the CPU unit) and S2=U1
(connection number 1) are specified by the UNITSEL instruction.
(Note 2)
By copying and pasting the following text in the instruction list box of FPWIN GR7, the operand part of
the above program can be input.
HTTPcCTL "ID0" "ENABLE"
List of operands
Operand
Description
Starting address of the device area that stores the string data that indicates a control target, or a
S1
character constant.
Starting address of the device area that stores the string data that indicates the control content
S2
(transfer enabled/disabled/canceled), or a character constant.
Devices that can be specified (indicated by ●)
Operan
d
W
W
X
Y
S1
S2
Outline of operation
● This instruction configures the settings for enabling or disabling transfers for an HTTP client.
● Before executing this instruction, use
the programming tool software "FPWIN GR7" to configure transfer settings.
● It takes some time to accept the processing of the transfer cancel request. After executing
the instruction, check the transfer status to see if the transfer stops. For details on checking
the transfer status, refer to
SMTP)".
17-98
16-Bit device:
W
W
W
S
D
L
R
L
S
D
T
D
"17.3 ETSTAT (Acquiring Ethernet Unit Information: FTP/HTTP/
32-Bit
device:
TS
TE
U
W
WI
C
C
M
O
S
E
"17.17 HTTPcSET (HTTP Client Transfer Setting)"
Real
Integer
numbe
r
D
IX
K
H
SF
F
WUME-FP7CPUPGR-12
St
rin
g
Index
modifie
r
" "
or